CO₂ Enrichment Calculator
Find the CO₂ level that suits your crop and light, how much CO₂ your space needs to hold it, and what the research says you gain
Room & Units
Crop & Light
Air Exchange & CO₂ Levels
Conditions
Exhaust & Vents
Dosing Dynamics
Sensor
Room Around the Tent
Measure My Room
Air-change test, lights off and nothing added (plants mask the result with the lights on).
Plant-uptake test, lights on and nothing added.
Enter your space's length, width and height; everything else starts from a sensible value you can change.
How this is calculated · Sources
The model in plain words
- Volume of the space: length × width × height.
- Gas density from temperature and elevation (ideal gas; air pressure from the US Standard Atmosphere). At 25 °C and sea level 1 litre of CO₂ weighs 1.799 g.
- Fill: raising the space from the incoming-air level to the target. 1 ppm in 1 m³ is 1 mL of gas at any temperature; only its weight changes.
- Leakage: air changes per hour × volume × (target − incoming air). The same well-mixed formula appears in 9 published formulations (8 peer-reviewed, 1 thesis).
- Plant uptake (estimate): canopy area × a measured canopy light and CO₂ response (Nederhoff & Vegter 1994), with a CO₂ compensation point of 50 ppm, anchored to measured lettuce, fruiting-crop and cannabis canopies and capped at 10 g/m²/h.
- Hold rate and daily total: leakage plus uptake while the lights are on, plus the fill, the refill after vent-open hours, exhaust-burst refills and any hours spent holding the outdoor level.
- CO₂ use efficiency: the share of the CO₂ added that the plants fix (Kozai 2013).
- Expected gain: the crop's published trial range, and the dose-response curve of a 630-experiment meta-analysis (Poorter et al. 2022).
Key assumptions
- One well-mixed space; the real gas differs from an ideal gas by about 0.5%, far below sensor accuracy.
- Night respiration is not credited. The carry-over option credits only CO₂ left from the previous day's enrichment after leakage decay. With 24-hour lighting there is no dark period, so the space is filled once at start-up, not every day.
- Vent-open hours are taken as one block within the lit period: the space falls to the incoming level and is refilled once when the vents close.
- Grow-tent leakage (1.5 air changes per hour) is assumed: no published measurement exists. Measure yours with the air-change test.
- The uptake model is fitted up to about 700 µmol/m²/s and is extrapolated above that.
- The gain curves rest mostly on 330-780 ppm data; above about 1,000 ppm they are low reliability.
- Gains are against air at the incoming-air level unless stated. Pot-study results under 5 litres are never shown as expected gains.
Health reference levels used
- 1,000 ppm: the most common indoor-air guideline value (43 guidelines, mostly about ventilation and odour, not toxicity).
- 5,000 ppm: health reference level averaged over up to 10 hours a day (NIOSH). In a 2.5-hour human study only exhaled CO₂ rose; no symptoms or performance change.
- 30,000 ppm: 15-minute health reference level (NIOSH). Mild headache, sweating and breathlessness after about 1 hour at around 3% (HSE); submarine crews kept at 3% were only slightly affected (NIOSH). At 2%, people at rest for 4 hours showed no acute effects (Maniscalco 2022); headache and breathlessness appeared at 4% (Ryan 2022, 2025).
- 40,000 ppm: "immediately dangerous" level (NIOSH). Headache and breathlessness within 12-30 minutes in human studies.
Evidence key
Peer-reviewed study; Meta-analysis or review; Conference paper (peer-reviewed); Thesis (examined); Dissertation (not peer-reviewed); Reference data (physical constants); Standard method (engineering standard, not peer-reviewed); Government research data. Figures marked "estimate" are calculations or syntheses, not measurements.
Visit Us In-Store: 2/322 Hobart Rd, Youngtown TAS